6KVA High Frequency Single Phase Power Supply Online UPS HP9116CR Series

Nkọwa dị mkpirikpi:

Voltage mmepụta: 220V


Nkọwa ngwaahịa

Nchịkọta

Nkọwa ngwa ngwa

Ebe amụrụ: Guangdong, China Arọ: ọzọ
Aha ika: SOROTEC Ụdị: N'ịntanetị
Nọmba nlereanya: HP9116CR/HP9316 1-20K Ngwa: Ngwa ngwa
Usoro: Otu Usoro Aha: Ups ike ọkọnọ
Nchedo: Overcurrent    

Ikike inye

Ikike ịnye:5000 Iberibe/Iberibe kwa ọnwa Onye njikwa chaja ikuku

Nkwakọ ngwaahịa & nnyefe

Nkọwa nkwakọ ngwaahịa: Katọn, mbupu ụdị mbupụ ma ọ bụ dị ka ihe achọrọ
Port: Shenzhen

Nkọwa ngwaahịa

10KVA High Frequency Single Phase Power Supply Online Ups HP9116CR HP9316CR Series Long Back Up1

 

Ngwa:

Sava, Ebe data, Ngwaọrụ netwọk dị egwu, eletrọnịkị nwere mmetụta, Telecom...

 

Atụmatụ:

1.Trendy LCD maka zuru ezu Real-Time UPS Ọnọdụ ngosi
2. Microprocessor njikwa na-ekwe nkwa ntụkwasị obi dị elu
3. Ejikọtara ya na Boost na Buck AVR iji kwado voltaji ntinye
4.Built-in DC mmalite ọrụ na-enyere UPS na-amalite na-enweghị AC ike ọnọ.
5. Ọdụ ụgbọ mmiri Smart RS-232 nwere ngwanrọ nbudata efu sitere na ịntanetị.
6.User-Replaceable Battery Design.
7.Auto ụgwọ n'agbanyeghị na UPS kwụsịrị.

 

8.Auto Malitegharịa ekwentị mgbe AC ​​mgbake.
9.Na-enye Modem/Phone line Surge Protection.
10.Na-enye mgbapu, nfefe, na nchekwa oke ibu.
11. USB / EPO fuctions

Nkọwapụta

Nlereanya HP9116CR 1-10KVA
1KR/1KR-XL 2KR/2KR-XL 3KR/3KR-XL 6KR/6KR-XL 10KR/10KR-XL
Ike 1KVA / 0.7KW 2KVA / 1.4KW 3KVA / 2.1KW 6KVA / 4.2KW 10KVA/7KW
Voltaji ọnụ 220/230/240VAC
Ugboro ugboro 50/60HZ
Ntinye
Oke voltaji 115 ~ 295VAC (± 3VAC) 176 ~ 297VAC (± 3VAC)
Oke ugboro ugboro 50HZ: (46 ~ 54HZ); 60HZ (56HZ ~ 64HZ)
Ihe kpatara ike > 0.98
Mpụta
Nkenke voltaji 220/230/240x (1±2%) VAC
Nkezi ugboro ugboro 50/60HZ±0.05HZ
Ihe kpatara ike 0.7/0.8 (nhọrọ)
Harmonic Distortion Ibu Linear <3% Ibu na-abụghị Linear<6%
Ibu Ibu Ike 110% ~ 150% maka 30sk; 150% maka 200ms 105% ~ 130% maka 10min; 130% maka 1 nkeji
Oke Crsst dị ugbu a 3:1
Oge mbufe 0ms(AC→DC)
Batrị
Voltaji DC 36VDC 96VDC 240VDC
Oge nchaji 5 awa ruo 90% (nhọrọ: 2KR/3KR ọkọlọtọ nlereanya batrị n'ime UPS)
Chajị ugbu a 1A 8A 1A 8A 1A 8A 2.0A/402A/5.6A(nhọrọ)
Panel Dispiay
LCD Ntinye aka na mmepụta voltaji, ugboro ugboro, voltaji batrị, ikike batrị, na pasent nke ibu
Nzikọrịta ozi
Interface nkwukọrịta RS232, SNMP kaadị(Nhọrọ),USB(Nhọrọ)
Environment na-arụ ọrụ
Okpomọkụ 0 ~ 40 ℃
iru mmiri 0 ~ 95% (anaghị ekpokọta ọnụ)
Okpomọkụ nchekwa -25 ℃ ~ 55 ℃
Elu <1500m
Ọkwa mkpọtụ(1m) <45DB <50DB
Njirimara Fisiks
Ibu NW 16.5 9 31 11.5 32 12.5 18.5 20.5 2224
GW 18.5 11.5 35 14.5 36 15 21.5 23.5 25 27
Akụkụ: (WxDxH) mm 447x450x89 440x600x130 447x450x89 447x600x130 447x450x89   447x600x130 447x600x177
2U 3U 2U 3U 2U 3U 4U
Nlereanya HP9316CR PLUS 10-20KVA
Ike ike(VA/W) 10KT-XL 15KT-XL 20KT-XL
Enyere ike 10KVA/9KW 15KVA / 13.5KW 20KVA/18KW
Ogo voltaji 208/220/230/40VAC
Ugboro ugboro 40-70 Hz (50/60 akpaaka-uche)
Ntinye
Oke voltaji 120 ~ 275VAC (± 3VAC)(220VAC/380VAC nhọrọ)
Ihe kpatara ike > 0.95 (Oge atọ) ≥0.99
Mpụta
Ụkpụrụ voltaji 208/220/230/240VAC (± 1%)
Iwu ugboro ugboro 50/60HZ±0.05 Hz
Ihe kpatara ike 0.9 0.8 0.9 0.8 0.9
THDV Ibu ahịrị <2%, Ibu na-abụghị nke eriri <5%
Ibu Ibu Ike 105% ~ 125% maka 10min; 125% ~ 150% maka 30s,>150% maka 500 ms
Ratio Crest dị ugbu a 3:1
Oge mbufe 0ms (ụdị AC → Ọnọdụ batrị)
Batrị
Voltaji DC 192VDC 192VDC 216VDC 240VDC 192VDC 216VDC 240VDC
Fanye ugbu a 4A 8A 4A 8A 4A
Ngosipụta
LCD Gosipụta ntinye/mpụta voltaji, Frequency, voltaji batrị, ikike batrị, ọnụego ibu.
Nkwukọrịta
Interface Smart RS232, SNMP kaadị (nhọrọ),USB (nhọrọ)
gburugburu
Okpomọkụ arụ ọrụ 0 ~ 40 ℃
iru mmiri 0 ~ 95% (anaghị ekpokọta ọnụ)
Okpomọkụ nchekwa -25 ℃ ~ 55 ℃
Altitude ọrụ <1500m
Ọkwa mkpọtụ (1m) <55dB
Njirimara Fisiks
Ibu(KG) 16.9 31
Akụkụ:(Wx D x H)mm 630X440X266

Mbukota & nnyefe